About this Product
The Kontrol Kube Negative Air Machine offers the perfect combination of power, efficacy, and convenience. Weighing in at 44 lbs., this negative air machine delivers a variable speed up to 500 CFM with the HEPA filter installed. Vital to all containment systems, it ensures all dust is captured, and is designed to work seamlessly with the Kontrol Kube Mobile Containment Unit. (Negative Air Machine comes equipped with the HEPA, DOP and Pre-Filters.)
The Kontrol Kube Negative Air Machine offers the perfect combination of power, efficacy, and convenience. Weighing in at 44 lbs., this negative air machine delivers a variable speed up to 500 CFM with the HEPA filter installed. Vital to all containment systems, it ensures all dust is captured, and is designed to work seamlessly with the Kontrol Kube Mobile Containment Unit. (Negative Air Machine comes equipped with the HEPA, DOP and Pre-Filters.)
Features
- 250 – 500 CFM (variable speed)
- 12” ductable intake
- Rotomolded plastic housing
- GFCI protected accessory outlet
- 25’ power cord
- 3 stage DOP compliant HEPA filtered
- Filter change indicator light
Accessories
First Stage Pre-Filter: High-quality filters restore negative air machines to full efficiency. Replace regularly to ensure maximum performance.
Second Stage DOP Compliance Filter: The addition of the 2nd stage DOP Filter Kit ensures one-pass HEPA filtration. This filter allows the Kontrol Kube Negative Air Machine to pass laboratory DOP testing conducted per ANSI standards, achieving an efficiency rating of 99.97% against oily aerosol particles down to 0.3 microns.
HEPA Filter: Kontrol Kube HEPA Filters combine filtration ability with filter capacity. To maximize filter life, be sure to change the first stage pre-filter regularly.
Carbon Filter: The Carbon Filter captures a variety of volatile organic compounds (VOCs), including soot and smoke, food odors, fumes from paint and paint thinners, sewer odors and many other compounds.
Operating Instructions Setup
1. Unwrap the cord wrap completely
2. Place the Negative Air Machine upright (vertical with handle at the top)
3. Plug in to a standard 115 volt outlet. Each Negative Air Machine needs 3 amps to operate.
4. To switch the unit on, locate the control panel and turn the variable speed switch clockwise to start the unit (see “Control Panel” below). Then select either a maximum (500 CFM) or down to a minimum (250 CFM) airflow rate. To maintain the optimal CFM, consult the IICRC S520 standards, 10.3.1.
5. The Complete Negative Air Machine is ideal for use with Kontrol Kube Containment Units. For more information, see full instruction guide Here