About this Product
Lead Shield Post Removal Lockdown by Fiberlock Technologies binds residual lead-based paint (LBP) and dust present after removal and accepts most topical coverings. Designed with a water based, 100% acrylic formula, Lead Shield can be used on interior and exterior surfaces. Lead Shield sprays on white and dries clear to permit visual inspection of any residual paint. Apply indoors or outdoors with a brush, roller or spray and follow all application instructions on label. Packaged in a 5-gallon container.
Fiberlock Technologies was founded upon the simple promise of providing the highest quality product and the best possible service to its customers while conducting business with the utmost integrity. Founded on the core beliefs that superior quality, definitive science and enduring service are the keys to corporate success, Fiberlock has grown to become one of the most respected names in the abatement and remediation industry.
Product Specifications:
- POST REMOVAL LOCKDOWN AND SEALANT: Bind residual lead-based paint and dust after removal with Lead Shield Post Removal Lockdown – one-step product bonds to most surfaces and accepts most topical coverings.
- WATER-BASED, 100% ACRYLIC FORMULA eliminates the need for sanding, priming and sizing recently stripped walls on most surfaces. Lead Shield sealer should not be used as a substitute for encapsulation.
- INTERIOR AND EXTERIOR APPLICATION: Prepare interior and exterior surfaces to accept a final topical covering with Lead Shield. For exterior applications, Lead Shield must be top coated with an exterior grade acrylic coating.
- READY TO USE: Apply Lead Shield uniformly with a brush, roller or spray. Stir thoroughly to achieve a uniform consistency and follow all application instructions on label. 5-gallon container.
- FOR OVER 35 YEARS, Fiberlock Technologies has manufactured products used to address environmental, safety and health hazards, becoming one of the most respected names in the abatement and remediation industry.
Lead Shield is a water based 100% acrylic lockdown with a dual purpose; it binds residual lead-based paint (LBP) and dust present after removal; and accepts most topical coverings. Lead Shield is a one-step product which bonds to most surfaces eliminating the need for sanding, priming and sizing recently stripped walls. Lead Shield can be used on both interior and exterior surfaces, and was expressly formulated to prepare these surfaces to accept a final topical covering. Lead Shield should not be used as a substitute for encapsulation.
- The clear version of this product sprays on white and dries clear to permit visual inspection of any residual paint.
- These unique features assist in obtaining final LBP removal certification.
- Eliminates the need for sanding and priming on most surfaces
- Water-based, 100% acrylic *For exterior applications
- LeadShield must be top coated with an exterior grade acrylic coating.
SURFACE PREPARATION
- Lead Shield must be applied when the atmosphere and surface temperatures exceed 50°F
- Surfaces must be free of all surface contamination prior to application of Lead Shield
- Patch any irregularities with vinyl patching paste or appropriate patching compound
- If chemical strippers were used to remove the paint, follow the manufacturers’ suggestions for surface cleaning before applying Lead Shield. Sanding, scraping and other surface preparation procedures can create toxic dust and hazardous waste
- A HEPA (High Efficiency Particulate Air) vacuum should be used on all surfaces to remove hazardous dust and particles
- Use MSHA/NIOSH approved or equivalent respiratory protection suitable for concentrations and types of air contaminants encountered
APPLICATION TOOLS & PROCEDURES
- Consult all related local, state, and federal regulations regarding work practices and personal protection prior to the application of Lead Shield
- Do not apply when air or surface temperature is below 50°F or when drying conditions are poor
- Lead Shield is supplied ready to use
- Apply Lead Shield uniformly by brush, roller, or spray
- Stir thoroughly to achieve a uniform consistency before selecting one of the recommended tool application methods below
TOOLS
- Brush: Synthetic, nylon or polyester
- Roller: 3/8” nap synthetic fiber
- Spray Settings: Pressure: 2000-3000 P.S.I. Tips: .015 to .021 tips
MIXING
- Mix thoroughly.
- Do not add solvents, oils or colors in oil, or mix with other paint types
DRYING TIME
- @ 70°F 50% R.H.
- To Touch – 30 minutes
- Recoat – 2 hours
COVERAGE
- Smooth Surfaces- 450 sq. ft. per gallon
- Porous Surfaces- 100-300 sq. ft. per gallon
CLEAN UP
- Clean tools and drippings with warm soapy water before Lead Shield dries
- Dispose of all waste according to all existing local, state and federal regulations
PRECAUTIONS
- Store in a dry place at temperatures between 40°F (4.5°C) and 90°F (32°C)
- Stir thoroughly. Do not mix with any other coatings, solvents or colors in oil
- Do not apply when air or surface temperature is below 50°F or when drying conditions are poor
- Do not re-coat with coatings using aromatic or other strong solvents
- When applying with a sprayer, wear a NIOSH approved respirator with any R, P, N or HE filter
- Use adequate ventilation during application
- Choosing a selection results in a full page refresh.
- Press the space key then arrow keys to make a selection.