Fiberlock Lead Barrier Compound III – Pro Solutions Direct

Fiberlock Lead Barrier Compound III

  • Load image into Gallery viewer, Fiberlock Lead Barrier Compound III
  • Load image into Gallery viewer, Fiberlock Lead Barrier Compound III
  • Load image into Gallery viewer, Fiberlock Lead Barrier Compound III
  • Load image into Gallery viewer, Fiberlock Lead Barrier Compound III
  • Load image into Gallery viewer, Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III
Fiberlock Lead Barrier Compound III

Fiberlock Lead Barrier Compound III

Regular price
$67.14
Sale price
$67.14
Regular price
$78.99
Unit price
per 
MFG SKU: 5801-1
Stock: Out of Stock In Stock

Many of our products have bulk discounts for customers in our Pro Program. Sign up for our Pro Program here.

Purchase Options
Delivery Frequency
Regular price
$67.14
Sale price
$67.14
Regular price
$78.99
Unit price
per 

About this Product

Lead Barrier Compound by Fiberlock Technologies forms a barrier between lead based paint and the environment, serving as a permanent method for abatement of lead based paint. Designed with a thermoplastic elastomeric blend, Lead Barrier Compound forms a durable yet flexible seal. Lead Barrier Compound is accepted for use in all 50 states and meets or exceeds all federal, state and local standards for covering lead based paint on interior or exterior surfaces. Follow all application instructions on label.

Fiberlock Technologies was founded upon the simple promise of providing the highest quality product and the best possible service to its customers while conducting business with the utmost integrity. Founded on the core beliefs that superior quality, definitive science and enduring service are the keys to corporate success, Fiberlock has grown to become one of the most respected names in the abatement and remediation industry.


Product Specifications:

  • INDUSTRIAL LEAD ENCAPSULANT: Form a barrier between lead based paint and the environment with Lead Barrier Compound (LBC) – serves as a permanent method for abatement of lead based paint.
  • THERMOPLASTIC ELASTOMERIC BLEND forms a durable yet flexible barrier between lead based paint and the environment. With a high-solids coating, Lead Barrier Compound offers unparalleled coverage, economics and aesthetics.
  • COMPLIES WITH ALL EPA AND HUD REQUIREMENTS: Lead Barrier Compound meets all federal, state and local standards for lead based encapsulants and meets or surpasses the ASTM E-1795 Standard. LBC is certified for use in all 50 states.
  • EASY TO APPLY AND CLEAN UP: Apply LBC with brush, roller or airless spray equipment. 14 wet mils are required to achieve the required minimum dry film thickness of 7 dry mils. Follow all application instructions on label.
  • FOR OVER 35 YEARS, Fiberlock Technologies has manufactured products used to address environmental, safety and health hazards, becoming one of the most respected names in the abatement and remediation industry. 

Product Benefits

  • For use in all 50 states
  • UL Classified
  • Class A fire rated
  • Contains a bitter tasting anti-ingestant

Typical Applications

  • Not recommended for use on friction or impact surfaces, or movable closures such as door jambs and window jambs. Residents may be present during brush or roller application but not in the immediate work area (i.e., same room).
  • LBC Type III will not protect occupants from ingestion of the encapsulated lead-based paint, if surface is damaged, broken or abraded. Surfaces coated with LBC Type III must be inspected routinely.
  • Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard.

APPLICATION TOOLS

  • Apply Fiberlock LBC with brush, roller or airless spray equipment.
  • Brush: Synthetic, nylon or polyester bristle
  • Roller: Synthetic Fiber 3/8”-1/2” nap roller
  • Spray Settings:  Pressure: 1300-2000 P.S.I. Tips: .015 to .021 tips

DRYING TIME

  • @ 70°F 50% R.H.
  • To Touch – 1-2 Hours
  • Recoat – 8-16 Hours

COVERAGE

  • 120 sq. ft. per gallon @ 14 wet mils

Usage Instructions

SURFACE PREPARATION

  • Carefully clean up with a wet mop and HEPA vacuum.
  • Mix thoroughly, preferably with an electric drill mounted device designed for blending liquid coatings. Clear liquid present when container is opened is an integral part of the product and must be mixed in completely.
  • LBC is supplied in a tintable white base, and may be tinted to light colors with two ounces or less of universal liquid colorant (per gallon). Field tinting by the end user or an unauthorized distributor, or the addition of more than two ounces of universal colorant will void all warranties. Medium or deep-base colors may be available please reach out directly to prosolutions@icpgroup.com
  • Prior to application of LBC, inspect all surfaces to ensure they are clean, dry and free of all contaminants including: dust, rust, grease, oil, mildew, glue size, calcimine, wax, soap, loose paint, or any other surface contaminant which may affect adhesion.
    • Use a vacuum with a HEPA filter specifically designed to capture hazardous dust and waste or wipe surfaces with a damp cloth.
    • Patch and repair irregularities in surfaces with appropriate patching compound. For high gloss or newly painted surfaces wet scour with Fiberlock’s LeadSafe Wipes or other approved surface preparation treatment.
    • Use a coarse scouring pad or similar tool, and/or liquid de-glossing agents to eliminate any gloss where necessary.
    • Rinse de-glossing agents as directed by manufacturer.
    • Wear proper personal protection for any cleaning product used as determined by the manufacturer. For detailed surface preparation and application instruction, please refer to LBC Specification or find other documents for this product in our resources section.

SURFACE PRIMING

  • Most surfaces do not require a primer coat. However, a primer is recommended for treating the following conditions:
    • Prime unpainted metal surfaces with a 100% acrylic rust inhibitive primer.
    • Prime water damaged surfaces with at 100% acrylic stain blocking primer.
    • Prime unpainted wood and drywall with a 100% acrylic universal primer.
    • Prime unpainted brick, masonry or block with a masonry conditioner.
    • Prime chalky surfaces with a chalk resistant primer.

APPLICATION TOOLS

  • Apply Fiberlock LBC with brush, roller or airless spray equipment.
  • Brush: Synthetic, nylon or polyester bristle
  • Roller: Synthetic Fiber 3/8”-1/2” nap roller
  • Spray Settings:  Pressure: 1300-2000 P.S.I. Tips: .015 to .021 tips

PRODUCT APPLICATION

  • Fiberlock LBC must be applied when air and surface temperatures are above 45°F at time of application and for 12 hours thereafter. 14 wet mils are required to achieve the required minimum dry fi lm thickness of 7 dry mils. Always use a wet mil gauge to measure coating thickness during application. Apply a minimum of 2 liberal coats when using a brush or roller.

DRYING TIME

  • @ 70°F 50% R.H.
  • To Touch – 1-2 Hours
  • Recoat – 8-16 Hours

COVERAGE

  • 120 sq. ft. per gallon @ 14 wet mils

CLEAN UP

  • Clean all tools and drippings with warm soapy water before LBC dries. Use a HEPA approved vacuum specifically designed to collect any hazardous dust and/ or waste generated. Dispose of all waste according to all current local, state and federal regulations.

PRECAUTIONS

  • Product is sensitive to heat and time.
  • Store in a dry place at temperatures between 40°F (4.5°C) and 90°F (32°C).
  • Do not store or apply at temperatures in excess of 100°F.
  • Rotate stock often.
  • Use product in a well ventilated area. If respiratory irritation develops increase ventilation and/or wear respiratory protection. Use a disposable spray-mist/dust respirator rated for filtering aerosol mist to avoid oral contact with bitter tasting, anti-ingestant ingredient when spraying.
  • When applying with a sprayer, wear a NIOSH approved respirator with any R, P, N or HE filter.
  • Avoid contact with eyes and skin. Wash hands after use.
  • LBC Type III will not protect occupants from ingestion of the encapsulated lead-based paint, if surface is damaged, broken or abraded. Surfaces coated with LBC Type III must be inspected routinely.
  • Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard.
  • Not recommended for use on friction or impact surfaces, or movable closures such as door jambs and window jambs. Residents may be present during brush or roller application but not in the immediate work area (i.e., same room).
  • Residents should not be present during spray application for worksite safety reasons.
  • Residents may return once application has ceased and LBC III is dry to the touch.
  • For use in all 50 states
  • UL Classified
  • Class A fire rated
  • Contains a bitter tasting anti-ingestant
  • Not recommended for use on friction or impact surfaces, or movable closures such as door jambs and window jambs. Residents may be present during brush or roller application but not in the immediate work area (i.e., same room).
  • LBC Type III will not protect occupants from ingestion of the encapsulated lead-based paint, if surface is damaged, broken or abraded. Surfaces coated with LBC Type III must be inspected routinely.
  • Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard.

APPLICATION TOOLS

  • Apply Fiberlock LBC with brush, roller or airless spray equipment.
  • Brush: Synthetic, nylon or polyester bristle
  • Roller: Synthetic Fiber 3/8”-1/2” nap roller
  • Spray Settings:  Pressure: 1300-2000 P.S.I. Tips: .015 to .021 tips

DRYING TIME

  • @ 70°F 50% R.H.
  • To Touch – 1-2 Hours
  • Recoat – 8-16 Hours

COVERAGE

  • 120 sq. ft. per gallon @ 14 wet mils

SURFACE PREPARATION

  • Carefully clean up with a wet mop and HEPA vacuum.
  • Mix thoroughly, preferably with an electric drill mounted device designed for blending liquid coatings. Clear liquid present when container is opened is an integral part of the product and must be mixed in completely.
  • LBC is supplied in a tintable white base, and may be tinted to light colors with two ounces or less of universal liquid colorant (per gallon). Field tinting by the end user or an unauthorized distributor, or the addition of more than two ounces of universal colorant will void all warranties. Medium or deep-base colors may be available please reach out directly to prosolutions@icpgroup.com
  • Prior to application of LBC, inspect all surfaces to ensure they are clean, dry and free of all contaminants including: dust, rust, grease, oil, mildew, glue size, calcimine, wax, soap, loose paint, or any other surface contaminant which may affect adhesion.
    • Use a vacuum with a HEPA filter specifically designed to capture hazardous dust and waste or wipe surfaces with a damp cloth.
    • Patch and repair irregularities in surfaces with appropriate patching compound. For high gloss or newly painted surfaces wet scour with Fiberlock’s LeadSafe Wipes or other approved surface preparation treatment.
    • Use a coarse scouring pad or similar tool, and/or liquid de-glossing agents to eliminate any gloss where necessary.
    • Rinse de-glossing agents as directed by manufacturer.
    • Wear proper personal protection for any cleaning product used as determined by the manufacturer. For detailed surface preparation and application instruction, please refer to LBC Specification or find other documents for this product in our resources section.

SURFACE PRIMING

  • Most surfaces do not require a primer coat. However, a primer is recommended for treating the following conditions:
    • Prime unpainted metal surfaces with a 100% acrylic rust inhibitive primer.
    • Prime water damaged surfaces with at 100% acrylic stain blocking primer.
    • Prime unpainted wood and drywall with a 100% acrylic universal primer.
    • Prime unpainted brick, masonry or block with a masonry conditioner.
    • Prime chalky surfaces with a chalk resistant primer.

APPLICATION TOOLS

  • Apply Fiberlock LBC with brush, roller or airless spray equipment.
  • Brush: Synthetic, nylon or polyester bristle
  • Roller: Synthetic Fiber 3/8”-1/2” nap roller
  • Spray Settings:  Pressure: 1300-2000 P.S.I. Tips: .015 to .021 tips

PRODUCT APPLICATION

  • Fiberlock LBC must be applied when air and surface temperatures are above 45°F at time of application and for 12 hours thereafter. 14 wet mils are required to achieve the required minimum dry fi lm thickness of 7 dry mils. Always use a wet mil gauge to measure coating thickness during application. Apply a minimum of 2 liberal coats when using a brush or roller.

DRYING TIME

  • @ 70°F 50% R.H.
  • To Touch – 1-2 Hours
  • Recoat – 8-16 Hours

COVERAGE

  • 120 sq. ft. per gallon @ 14 wet mils

CLEAN UP

  • Clean all tools and drippings with warm soapy water before LBC dries. Use a HEPA approved vacuum specifically designed to collect any hazardous dust and/ or waste generated. Dispose of all waste according to all current local, state and federal regulations.

PRECAUTIONS

  • Product is sensitive to heat and time.
  • Store in a dry place at temperatures between 40°F (4.5°C) and 90°F (32°C).
  • Do not store or apply at temperatures in excess of 100°F.
  • Rotate stock often.
  • Use product in a well ventilated area. If respiratory irritation develops increase ventilation and/or wear respiratory protection. Use a disposable spray-mist/dust respirator rated for filtering aerosol mist to avoid oral contact with bitter tasting, anti-ingestant ingredient when spraying.
  • When applying with a sprayer, wear a NIOSH approved respirator with any R, P, N or HE filter.
  • Avoid contact with eyes and skin. Wash hands after use.
  • LBC Type III will not protect occupants from ingestion of the encapsulated lead-based paint, if surface is damaged, broken or abraded. Surfaces coated with LBC Type III must be inspected routinely.
  • Damaged surfaces should be repaired and re-encapsulated immediately to prevent exposure to the lead hazard.
  • Not recommended for use on friction or impact surfaces, or movable closures such as door jambs and window jambs. Residents may be present during brush or roller application but not in the immediate work area (i.e., same room).
  • Residents should not be present during spray application for worksite safety reasons.
  • Residents may return once application has ceased and LBC III is dry to the touch.

LBC 10 Point Specification

Design Services Lead Encapsulation AIA Specification

 